Thanks for the reply,
It is an LSI card, the same one that was in my truenas server.
This one bought here
Edit: also the command that bricked the drive was me using sg_format with --size==512
Is that the same formatting solution you were mentioning ? Is it different?










Thanks for the continued support! ❤
I’ve attached an identical Segate SAS drive from the server.
To confirm, it is the same LSI card that was in the TrueNAS server. I pulled it out of the server and put it into the trouble shooting machine, where I run the commands.
It is this one: 01:00.0 Serial Attached SCSI controller [0107]: Broadcom / LSI SAS2308 PCI-Express Fusion-MPT SAS-2 [1000:0087] (rev 05)
I did not see your other reply lol, I will also try this command that you recommended:
sudo sg_format –format –size=512 –fmtpinfo=0 –pfu=0 /dev/sdb
Also, the sg_format ran for less than 5 minutes, very quick. However, if I can recall, it did say it was completed.
**Note: ** “Bricked Drive” turned to sdb
Identical working drive installed as sda
Here is the dmesg -T > dmesg-full.txt with the identical drive
Here is the code from: (with the output for each drive, separately)
sudo lspci -nnkvv
sudo lsblk -o NAME,MODEL,SIZE,PHY-SeC,LOG-SeC,ROTA
sudo fdisk -l /dev/sdX
sudo sg_inq -vv /dev/sdX
sudo sg_readcap -ll /dev/sdX
sudo sg_modes -a /dev/sdX
sudo sg_vpd -a /dev/sdX
Thanks again for all the help, I await your reply. :)
I will let you know the results of (sudo sg_format –format –size=512 –fmtpinfo=0 –pfu=0 /dev/sdb), as soon as it’s done.